Nuclear Power Plant Instrument Selection Charts

Model

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FM-9W-IC-25HT

NPP Process Monitor

Systems

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Nuclear Power Plant Process Monitor. Digital. Rack Mounted. Safety Class Qualified for NPP use. Detects Gamma, rejects thermal Neutron, Alpha, Beta. High pressure sealed ionization chamber with mineral insulated cable. (2) Electronics: Single or multichannel. (1) single channel (FM-9W). (1) multichannel (FM-9WHUB). Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

RMS REPAIR & REPLACEMENT NPP

Repair/Replacement

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Nuclear Power Plant Repair/Replacement: Detectors and Monitors. Problem: detectors and monitors break, degrade or replacement parts are no longer available. Technical Associates fills this need: Build an Exact Fit & Function Replacement Detector with Same or Longer Life Span, Use Highest Quality Parts & Components, Often the Same Brand as Original, Reasonable Pricing, Rebuild “Burned Out” Detectors Scheduled for Discard, Providing Dependable, Perfectly Working Spares.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ORO

Radiation System Overview

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Overhoff Radiation Overview. Digital. Installed. Map the facility in a series of views linking multiple instruments, installed and portable, and readings from a variety of areas to the facility mainframe and/or individually in each area including the perimeter. Software package: readout, mapping, reporting. Easy integration into facility mainframe. Wide variety of reports is available.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TA-RMS

NPP Monitor System

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Nuclear Power Plant Monitoring System. Digital. Rack or Wall Mounted. Multichannel electronics (FM-9WHUB). Accommodates a complete range of detectors & monitors including air, stack, liquid effluent, and particulate; Alpha, Beta, Gamma, Noble Gas, Tritium, Neutron. Facility-wide, specific buildings or areas. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface. Easy integration into facility mainframe.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

High Range Underwater Monitor. Digital. Portable. Four ranges to One Million R/hr. Includes
DMU-1 Ion Chamber. OPTIONAL: Other detectors and sensitivities. Detects
Beta-Gamma Radiation. Reads Out in R/hr. Optional 8 ft length including coupling. The Engineering unit read Out in Sieverts is also available.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

CP-MU-10K

Submersible Probe System

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Portable High Range Submersible Ion Chamber

Digital. Portable. Designed for hot cell monitoring of Reactor Spent Fuel Elements. Reads 0.1 to 10,0000 R/hr. The monitor consists of a lightweight 6 AA cell operated, solid-state, and MOSFET driven electronic package (Model CP-MU) coupled to a High Range DMU-100 Detector System consisting of 60 feet of special low noise cable with a waterproof coupling to the detector. The Engineering unit read Out in Sieverts also available.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

D2O-LO-HI

Deuterium Water Monitor

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Deuterium Water Monitor is a Continuous Real-Time water monitor to measure levels of deuterium. Installed or rack-mounted.

D2O or heavy water is used as the moderator in pressurized heavy water nuclear reactors. D2O is also used in obesity studies and other medical, biological, and pharmaceutical research.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

DMU-1
DMU-1000

Submersible High Capacity Probe

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Submersible High Capacity Ion Chamber Probes.

Used with the CP-MU series of electronics. Optional sleeving sets.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FPT Series

Fuel Pool Tool

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Fuel Pool Tool. Digital. Installed. Digital. Installed. Detects Tritium in NPP pool water, pool room air condensation. Monitors pool water temperature. (2) models: (1) Tritium only (FPT-H3). (1) Tritium plus Alpha-Beta-Gamma Detectors (FPT-H3-ABG). Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Laundry Sorter

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Laundry Monitor. Digital. Installed. Detects Beta. Dual fast flow sorting (clean vs contaminated) conveyor belts. (4) 6” x 6” Scintillation detectors mounted in a conveyor belt rack. Electronics: Wall or Rack Mounted. (4) channels with audio/visual alarms for each channel. Sensitive area 352 inches (230 cm2) each detector. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Laundry Sorter/A-B

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Laundry Monitor. Digital. Installed. Detects Beta/Gamma. Dual fast flow sorting (clean vs contaminated) conveyor belts. Detectors mounted above and below the conveyor belt. (6) 8” x 8” Beta scintillation detectors mounted above a conveyor belt in a conveyor belt rack. Sensitive area 642 inches (412 cm2) each detector. (4) 2” x 12” Gamma scintillation detectors mounted below the conveyor belt. Sensitive area 242 inches (155 cm2) each detector. Electronics: Wall or Rack Mounted. (10) channels, audio/visual alarms each channel. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Tritium in Water

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Tritium in Water Monitor Real-Time Continuous Series. Digital. Bench Top. Low activity (LIQ-X-LO). Mid activity (LIQ-X-HI). High activity (LIQ-X-HI). Data archive/retrieval. Local and remote alarm, readout, and monitoring.  Computer interface. Complies with relevant sections of ANSI 42.17A & N.42.18.
NOTE: For low-level Tritium see Nex-Tritium H2O.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Thorium Reactor Water

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Thorium Reactor Continuous Real-Time Water Monitor. Digital. Installed. Multi-detector monitor for Molten Salt Thorium Reactors. Real-time simultaneous measuring of Alpha, Beta (including Thorium 232) Gamma, and Tritium. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Sea Water Monitor

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Sea Water Monitor Continuous Real-Time. Digital. Installed. Multichannel Analyzer (MCA). Multidetector system for Alpha, Beta, and Gamma in seawater. Monitor liquid effluent around sea water-cooled nuclear power plants and desalination plants. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface. Computer interface. UV Lamp: Used on the inlet as an algaecide.
Optional: Ozone System.
Optional: Tritium detection.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Nuclear Power Water

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Nuclear Power Water Monitor Continuous Real-Time. Digital. Installed. Detects Alpha, Beta, and Gamma in Nuclear Power water. Multichannel Analyzer (MCA).
(6) models depending on detector type. Alpha, Beta, Gamma scintillation detectors. Gamma detector choice scintillation or Germanium (HPGe). Monitor liquid effluent from nuclear power plants. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. UV Lamp: Used on the inlet as an algaecide.
Optional: Tritium, C-14, Radon detection.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strap-On Pipe Monitor Series Continuous Real-Time. Digital. Installed. Flow rate is not a factor. Constant check and alarm. Single-channel (SCA) and multichannel analyzer (MCA) models. Local and remote alarm, readout, and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PEMO-7LE

Strap-On Pipe Monitor/P

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strap-On Pipe Monitor Series. Digital. Portable. Flow rate is not a factor. Constant check and alarm. Single channel (SCA) and multichannel analyzer (MCA) models. Local and remote alarm, readout, and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .